How large FFTs can pull signals out of the noise floor?











up vote
5
down vote

favorite
1












I am trying to detect unknown RF tones around -140 dBm and my scan BW is 5 MHz, going through the Noise power calculations the signal is below the thermal noise based on the scan BW. I read that using large FFTs can help to pull signals out of the noise floor. My question is how large FFTs can accomplish this?



The receiver used is an RFIC (LNA, Filter and ADC), and I was thinking FFTs of the order of 2¹⁶ or higher running on a hardware accelerator.



The unknown RF signals are ERP emissions from electronic devices which have RF circuitry.










share|improve this question









New contributor




luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.




















  • Does this need to happen at sample rate ("real-time")? Because $2^{16}$ is a relatively benign FFT length and my PC does that in real-time every $frac{2^{16}}{5cdot10^6,text{Hz}}=13,text{ms}$.
    – Marcus Müller
    2 days ago










  • Also, what kind of info do you want to gain out of this? Do you know the emission's frequencies and just need power, or do you really want a (pseudo)spectrum?
    – Marcus Müller
    2 days ago










  • @MarcusMüller, we are using hardware accelerator to implement the FFT which is not a processor based calculation. We want to achieve real-time but your number 13ms is a really good number. Those emissions might be in some well known freqs like 2.4GHz, 5.8GHz, etc.
    – luffyKun
    yesterday










  • cough 13 ms is, as my calculation indicated, what you need to have to fulfill any real-time constraints. Verify your computer can't do that with just plain CPU execution before you start programming an accelerator, is my humble design advice.
    – Marcus Müller
    yesterday















up vote
5
down vote

favorite
1












I am trying to detect unknown RF tones around -140 dBm and my scan BW is 5 MHz, going through the Noise power calculations the signal is below the thermal noise based on the scan BW. I read that using large FFTs can help to pull signals out of the noise floor. My question is how large FFTs can accomplish this?



The receiver used is an RFIC (LNA, Filter and ADC), and I was thinking FFTs of the order of 2¹⁶ or higher running on a hardware accelerator.



The unknown RF signals are ERP emissions from electronic devices which have RF circuitry.










share|improve this question









New contributor




luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.




















  • Does this need to happen at sample rate ("real-time")? Because $2^{16}$ is a relatively benign FFT length and my PC does that in real-time every $frac{2^{16}}{5cdot10^6,text{Hz}}=13,text{ms}$.
    – Marcus Müller
    2 days ago










  • Also, what kind of info do you want to gain out of this? Do you know the emission's frequencies and just need power, or do you really want a (pseudo)spectrum?
    – Marcus Müller
    2 days ago










  • @MarcusMüller, we are using hardware accelerator to implement the FFT which is not a processor based calculation. We want to achieve real-time but your number 13ms is a really good number. Those emissions might be in some well known freqs like 2.4GHz, 5.8GHz, etc.
    – luffyKun
    yesterday










  • cough 13 ms is, as my calculation indicated, what you need to have to fulfill any real-time constraints. Verify your computer can't do that with just plain CPU execution before you start programming an accelerator, is my humble design advice.
    – Marcus Müller
    yesterday













up vote
5
down vote

favorite
1









up vote
5
down vote

favorite
1






1





I am trying to detect unknown RF tones around -140 dBm and my scan BW is 5 MHz, going through the Noise power calculations the signal is below the thermal noise based on the scan BW. I read that using large FFTs can help to pull signals out of the noise floor. My question is how large FFTs can accomplish this?



The receiver used is an RFIC (LNA, Filter and ADC), and I was thinking FFTs of the order of 2¹⁶ or higher running on a hardware accelerator.



The unknown RF signals are ERP emissions from electronic devices which have RF circuitry.










share|improve this question









New contributor




luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.











I am trying to detect unknown RF tones around -140 dBm and my scan BW is 5 MHz, going through the Noise power calculations the signal is below the thermal noise based on the scan BW. I read that using large FFTs can help to pull signals out of the noise floor. My question is how large FFTs can accomplish this?



The receiver used is an RFIC (LNA, Filter and ADC), and I was thinking FFTs of the order of 2¹⁶ or higher running on a hardware accelerator.



The unknown RF signals are ERP emissions from electronic devices which have RF circuitry.







fft






share|improve this question









New contributor




luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.











share|improve this question









New contributor




luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.









share|improve this question




share|improve this question








edited 2 days ago









Marcus Müller

11.3k41431




11.3k41431






New contributor




luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.









asked Nov 27 at 22:33









luffyKun

284




284




New contributor




luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.





New contributor





luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.






luffyKun is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.












  • Does this need to happen at sample rate ("real-time")? Because $2^{16}$ is a relatively benign FFT length and my PC does that in real-time every $frac{2^{16}}{5cdot10^6,text{Hz}}=13,text{ms}$.
    – Marcus Müller
    2 days ago










  • Also, what kind of info do you want to gain out of this? Do you know the emission's frequencies and just need power, or do you really want a (pseudo)spectrum?
    – Marcus Müller
    2 days ago










  • @MarcusMüller, we are using hardware accelerator to implement the FFT which is not a processor based calculation. We want to achieve real-time but your number 13ms is a really good number. Those emissions might be in some well known freqs like 2.4GHz, 5.8GHz, etc.
    – luffyKun
    yesterday










  • cough 13 ms is, as my calculation indicated, what you need to have to fulfill any real-time constraints. Verify your computer can't do that with just plain CPU execution before you start programming an accelerator, is my humble design advice.
    – Marcus Müller
    yesterday


















  • Does this need to happen at sample rate ("real-time")? Because $2^{16}$ is a relatively benign FFT length and my PC does that in real-time every $frac{2^{16}}{5cdot10^6,text{Hz}}=13,text{ms}$.
    – Marcus Müller
    2 days ago










  • Also, what kind of info do you want to gain out of this? Do you know the emission's frequencies and just need power, or do you really want a (pseudo)spectrum?
    – Marcus Müller
    2 days ago










  • @MarcusMüller, we are using hardware accelerator to implement the FFT which is not a processor based calculation. We want to achieve real-time but your number 13ms is a really good number. Those emissions might be in some well known freqs like 2.4GHz, 5.8GHz, etc.
    – luffyKun
    yesterday










  • cough 13 ms is, as my calculation indicated, what you need to have to fulfill any real-time constraints. Verify your computer can't do that with just plain CPU execution before you start programming an accelerator, is my humble design advice.
    – Marcus Müller
    yesterday
















Does this need to happen at sample rate ("real-time")? Because $2^{16}$ is a relatively benign FFT length and my PC does that in real-time every $frac{2^{16}}{5cdot10^6,text{Hz}}=13,text{ms}$.
– Marcus Müller
2 days ago




Does this need to happen at sample rate ("real-time")? Because $2^{16}$ is a relatively benign FFT length and my PC does that in real-time every $frac{2^{16}}{5cdot10^6,text{Hz}}=13,text{ms}$.
– Marcus Müller
2 days ago












Also, what kind of info do you want to gain out of this? Do you know the emission's frequencies and just need power, or do you really want a (pseudo)spectrum?
– Marcus Müller
2 days ago




Also, what kind of info do you want to gain out of this? Do you know the emission's frequencies and just need power, or do you really want a (pseudo)spectrum?
– Marcus Müller
2 days ago












@MarcusMüller, we are using hardware accelerator to implement the FFT which is not a processor based calculation. We want to achieve real-time but your number 13ms is a really good number. Those emissions might be in some well known freqs like 2.4GHz, 5.8GHz, etc.
– luffyKun
yesterday




@MarcusMüller, we are using hardware accelerator to implement the FFT which is not a processor based calculation. We want to achieve real-time but your number 13ms is a really good number. Those emissions might be in some well known freqs like 2.4GHz, 5.8GHz, etc.
– luffyKun
yesterday












cough 13 ms is, as my calculation indicated, what you need to have to fulfill any real-time constraints. Verify your computer can't do that with just plain CPU execution before you start programming an accelerator, is my humble design advice.
– Marcus Müller
yesterday




cough 13 ms is, as my calculation indicated, what you need to have to fulfill any real-time constraints. Verify your computer can't do that with just plain CPU execution before you start programming an accelerator, is my humble design advice.
– Marcus Müller
yesterday










3 Answers
3






active

oldest

votes

















up vote
4
down vote



accepted










65,536 point FFT, assuming a 3 dB overall receiver noise figure and a 7.5 MHz FFT sampling rate of a digitally down-coverted 5 MHz bandpass signal.



Sub-band the 5 MHz bandwidth if you have the time margin for post processing, and the number of points needed goes down accordingly.



To meet your objective we basically need a receiver with a resolution bandwidth of 126 Hz or less (assuming the 3 dB noise figure stated), as long as the -140 dBm power level stated for the signal of interest is in an occupied bandwidth of less than this. Notice the point of interest to determine our ability to detect is not what the total power is, but what is the power per unit Hz; the power spectral density!



Let me explain...



Both what Marcus and Stanley said are quite good and this will add some practicality to what you are doing specific to your "below the noise assumptions". It is a bit of a misnomer to say that the signal is below the noise when we only consider total power in a given bandwidth. What we really want to look at is power spectral density (power per unit Hz) of the signal as compared to the noise and then decide if it is truly below the noise floor or not.(the power spectral density of the demodulated signal at the decision detector specifically when we "match filter", which from your description does not sound like doing any demodulation is feasible in your case). If it is truly below the noise floor, then we are challenged. So as long as the power spectral density of the signal is well above that of the noise, we can proceed with simple techniques of detection.



You mention a "scan BW" which can imply you are actually "scanning" by translating an input frequency from an observation of a 5 MHz bandwidth of interest through a narrow observation filter and then to a detector OR you are sampling a 5 MHz bandwidth of interest and taking a FFT (which is consistent with the rest of your description). Either approach can be used and you see both in the implementation of Spectrum Analyzer instruments. I assume the use of the word "scan" is figurative and you are sampling an analog BW of 5 MHz and then "scanning" by taking a FFT of that bandwidth. (Which is a very reasonable approach to take). However if you were actually scanning, the rate of scan would be important to limit. I don't think you are doing that, so I won't go into the further considerations of scan rate.



Consistent with Stanley's first point, you really need to understand the average occupied bandwidth of these "unknown tones" when specifying their expected power level. Just to clarify first any "matched filtering" techniques: If we knew anything further about the time varying characteristics of the "tones", we could use matched filtering techniques to optimize detection, consistent with what Marcus was pointing out with the FFT as just one example of doing that; which is a good choice for the detection of pure tones specifically up to the limits of our own oscillator phase noise and stability in our receiver--- Stanley is spot on in that pure tones don't exist, so reality sets a limit on how far we can take that, and further since you called these "unknown" and hinted this is EMI radiation noise I suspect that any other elaborate matched filtering techniques would not be easily done. (However! If you do know of particular patterns the electronics is doing, then that could indeed be exploited). Another example of using this technique to pull signals "out of the noise" is CDMA where for example Walsh codes could be used; here we know the signals are modulated by those specific codes, so we can "match" them in the receiver to provide the correlation gain described. It is interesting to compare the decoding matrix for the FFT (or OFDM specifically) to Walsh codes; in both cases we are correlating to code sequences; the Walsh codes are all two symbols (1, -1) while the FFT allows for doing the same thing with a full complex set on the unit circle.



However without knowing such detailed information about the transmitted signal, the first strategy would be simple bandpass filtering if the actual occupied power spectral density of the signal of interest is higher than our limit set by the thermal noise floor.



Let's go through a calculation to see what bandwidth you would need and what considerations you would make and how this "simple bandpass filtering" requirement translates to number of points needed in the FFT.



First we need to decide on a detection margin, typical numbers range from +6 dB to +12 dB, and are derived from probability of false alarm vs probability of detection which is the trade space. For simple computation I will use a reasonable number of +10 dB. This means if the noise in my detector is 10 dB below the signal of interest, I can make a reasonably confident detection on the presence of the signal.



Specifically for this case with AWGN noise the probability of false alarm would be $2 Q(3.16) = 0.16%$ from $10^{10 text{ dB}/20} = 3.16$ and the related area under the tails of the Gaussian distribution.



Given the signal level of -140 dBm, this implies a desired noise floor of -150 dBm.



To know what our noise floor is for a given filtering bandwidth, we need to know the receiver noise figure, which must account for all noise contributions up to the detector (including ADC quantization noise which can be included in a classical cascaded noise figure calculation). For purpose of proceeding with this example, I will assume a receiver noise figure of 3 dB. (You can change this to whatever your noise figure is, but given your objective, you would want to be sure you know what this is and that it is well designed).



Therefore the noise floor density is $-174 text{ dBm/Hz} + 3 text{ dB} = -171 text{ dBm/Hz}$, where $-174 text{ dBm/Hz}$ is the thermal noise floor at room temperature as computed from Boltzmann's constant and the temperature ($kT$).



For a total noise power of -150 dBm, which is 21 dB above the noise density, this is an implied bandwidth of $10^{21/10}= 126 text{ Hz} $



If you know that the signal of interest occupies a bandwidth of 126 Hz or less, or more specifically in that bandwidth maintains a power level of -140 dBm or more, then you have every opportunity to detect that signal with simple digital filtering techniques (just filter the occupied bandwidth). You can change the numbers above based on your actual system, but this would be the first thing I would look at in terms of getting there simply.



If you want more information such as what specific frequency that signal may be in, or if you know the signal meets that constraint but from measurement to measurement the signal location may change, or it occupies several of these bandwidth "bins", then the FFT is an excellent choice for that since it is essentially a bank of such filters.



This drives the minimum number of points required in the FFT which sets the resolution bandwidth (RBW) given that $RBW = f_s/N$ where N is the number of non-padded FFT samples. You didn't mention the sampling rate of your ADC or more specifically the sampling rate at the FFT computation, but for practical reasons I will assume a minimum sampling rate of 7.5 MHz at the FFT computation (allowing for simple anti-alias filtering ahead of your ADC, and ADC 5 MHz bandpass sampling of a real signal. Therefore to achieve the desired resolution bandwidth of 126 Hz, the number of points required in the FFT must be:



$$7.5 text{ MHz}/ 126 text{ Hz} = 59,500$$



Taking advantage of radix-2 implementations, I would use the next higher power of 2 to get $2^{16} = 65,536$ points



At this point there are several strategies to achieve this if not directly (such as sub-banding if you have post-processing time but limited resources), so the main point is to know what is the spectral density of your signal, and what is the actual noise floor (noise figure) of your receiver. In terms of spectral density, not total power but power / Hz, as long as the signal is indeed NOT below your noise, then detecting the signal will be no issue.






share|improve this answer























  • I can see how an FFT can pull out the signal based on spectral density of the signal and not the total power where it was my oversight. By scanning, it has 2 meanings in this project, first, scanning for a signal in the occupied bandwidth and second, scanning throughout some well known frequencies like 2.4GHz, 5.8GHz, etc using the same 5Mhz BW.
    – luffyKun
    yesterday










  • Yes so as long as you have sufficient margin against the theoretical thermal noise floor limits (and design your receiver properly)- doing that should not be overly challenging — it is straight forward to capture a 5 MHz band with an ADC and to do the FFT on the data and further post process. The key is if the spectral density of the signal is above the spectral density of the noise. To check your receiver noise floor, you can terminate your antenna port and do a capture, and then repeat with a calibrated input signal through the antenna connector port — a tone should suffice unless ...
    – Dan Boschen
    yesterday










  • you have excessive passband ripple (which is why true noise figure measurements measure receiver gain using elevated /calibrated noise sources that have a flat response across the passband of interest... if you have +/-1 dB of passband ripple then your noise figure measurement could be off by up to +/- 1 dB. I hope that makes sense. Bottom line in this comment is to validate where your noise floor sensitivity is and how far off you are from the theoretical limit established by $kTB$. By doing this test through your whole system including the FFT computation you will account for all factors.
    – Dan Boschen
    yesterday


















up vote
7
down vote













If you look at the formula of a single DFT bin



$$X[k] = sum_{n=0}^{N-1}x[n]e^{-j2pi kfrac nN}text,$$



you'll notice that his is essentially a correlation of $x$ with the complex sinusoid $e^{-j2pi kfrac nN}$.



That means the DFT can just be understood as a filter bank of matched filters for single tones that fall in the DFT "raster".



Hence, you simply get FFT length-based processing gain: The length of the sum.



But: you probably don't have perfect knowledge of the exact frequency of the signal you're trying to detect¹! So, you can't put things into that perfect DFT raster.



Now, the larger you choose the FFT length $N$, the finer that raster will get, but also, the longer your observation has to be, and the more compute power you'll need.



At some point, the DFT stops being the best possible tone detector, and superresolution techniques become relevant. In this case (weak tone, you're sure that you've only got exactly one tone in your signal), the ESPRIT algorithm with a long observation period leading to the autocovariance matrix estimate that it takes as input, would probably work very nicely.




¹ There's inevitably frequency error in your receiver, and in your transmitter. Papers that start with We assume perfect synchronization typically skip the hard part of making a system work...




share|improve this answer























  • the matched filter is out performed by ESPRIT? I don’t think so
    – Stanley Pawlukiewicz
    Nov 28 at 5:48










  • no, but the filter is only matched if you "hit" the frequency of that bin perfectly – which you, in an estimation problem, don't. (Otherwise: Welch's method, don't do the full FFT).
    – Marcus Müller
    Nov 28 at 11:41












  • the loss of a small mismatch that gets smaller as you lengthen will outperform a nonlinear estimators threshold behavior. no matched filter is perfect. ESPIRIT assumes white noise as well. No sample autocorrelation matrix is perfectly rotational either. A DFT bank is mote robust
    – Stanley Pawlukiewicz
    Nov 28 at 12:34










  • Well, don't forget that you redistribute your tone's energy over multiple bin according to a sinc shape in a DFT. The point is that we need to compare the variance in AWGN of the energy estimate of an "falls in the middle between two bins" tone of an $N$-point DFT's $max |cdot|$ with the variance of an ESPRIT estimate that incorporated the same $N$ samples into its autocorrelation matrix estimate.
    – Marcus Müller
    Nov 28 at 13:13






  • 1




    @Marcus, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:29


















up vote
5
down vote













To say there are only 2 problems with DFT based detection of weak tones would be wrong but I’m going to ignore myself and say there are two problems.



Problem 1:



A pure tone is a rare thing. It has to exist forever and never deviate from its tonal form. Real tones turn on and off, fade, and drift, and are often a component of a more complex waveforms. A real tone has bandwidth. One cannot arbitrarily increase the length of a DFT. One can run out of signal. One can over resolve a tone. One’s local time reference isn’t perfect.



Problem 2



Neglecting things like heavy tailed nonGaussian correlated noise and the tendency of real situations to have other tonal components in proximity, like looking for a weak tone in the presence of a unknown number of other tones.



An M point DFT produces M outputs. You need to pick the correct bin. This generally comes down to the “correct” bin being a reliable local maximum. The detection statistics of the maximum of a set of correlated bins is a hard problem. One usually relies on heuristics.



The finite observation and over resolution problem can be mitigated to some extent by combining coherent and incoherent gain. That is, averaging a bin amplitude over some number of coherent DFTs.



The DFT is not a consistent estimator. It doesn’t reduce the noise variance as the length of the DFT increases but it does provide SNR gain providing the tone is essentially tonal over its time window.



Averaging the bin power or bin magnitude does reduce variance. The combination of coherent and incoherent processing is a consistent estimate.



In a real application, one needs to find that sweet spot.



Im not telling you not to use a covariance based frequency estimator. ESPIRT was originally developed to solve a direction finding problem in array processing. It works well but there are a different set of tradeoffs in array processing even if the mathematics are nearly the same.






share|improve this answer





















  • Just now saw this answer! Awesome!
    – Marcus Müller
    Nov 28 at 17:54










  • @Stanley, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:38










  • I can’t say that Ive ever run a DFT that large. Expect to do some trial and error. I assume you are looking for a 20Hz BW
    – Stanley Pawlukiewicz
    Nov 28 at 21:50











Your Answer





StackExchange.ifUsing("editor", function () {
return StackExchange.using("mathjaxEditing", function () {
StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix) {
StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["$", "$"], ["\\(","\\)"]]);
});
});
}, "mathjax-editing");

StackExchange.ready(function() {
var channelOptions = {
tags: "".split(" "),
id: "295"
};
initTagRenderer("".split(" "), "".split(" "), channelOptions);

StackExchange.using("externalEditor", function() {
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled) {
StackExchange.using("snippets", function() {
createEditor();
});
}
else {
createEditor();
}
});

function createEditor() {
StackExchange.prepareEditor({
heartbeatType: 'answer',
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader: {
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
},
noCode: true, onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
});


}
});






luffyKun is a new contributor. Be nice, and check out our Code of Conduct.










draft saved

draft discarded


















StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdsp.stackexchange.com%2fquestions%2f53709%2fhow-large-ffts-can-pull-signals-out-of-the-noise-floor%23new-answer', 'question_page');
}
);

Post as a guest















Required, but never shown

























3 Answers
3






active

oldest

votes








3 Answers
3






active

oldest

votes









active

oldest

votes






active

oldest

votes








up vote
4
down vote



accepted










65,536 point FFT, assuming a 3 dB overall receiver noise figure and a 7.5 MHz FFT sampling rate of a digitally down-coverted 5 MHz bandpass signal.



Sub-band the 5 MHz bandwidth if you have the time margin for post processing, and the number of points needed goes down accordingly.



To meet your objective we basically need a receiver with a resolution bandwidth of 126 Hz or less (assuming the 3 dB noise figure stated), as long as the -140 dBm power level stated for the signal of interest is in an occupied bandwidth of less than this. Notice the point of interest to determine our ability to detect is not what the total power is, but what is the power per unit Hz; the power spectral density!



Let me explain...



Both what Marcus and Stanley said are quite good and this will add some practicality to what you are doing specific to your "below the noise assumptions". It is a bit of a misnomer to say that the signal is below the noise when we only consider total power in a given bandwidth. What we really want to look at is power spectral density (power per unit Hz) of the signal as compared to the noise and then decide if it is truly below the noise floor or not.(the power spectral density of the demodulated signal at the decision detector specifically when we "match filter", which from your description does not sound like doing any demodulation is feasible in your case). If it is truly below the noise floor, then we are challenged. So as long as the power spectral density of the signal is well above that of the noise, we can proceed with simple techniques of detection.



You mention a "scan BW" which can imply you are actually "scanning" by translating an input frequency from an observation of a 5 MHz bandwidth of interest through a narrow observation filter and then to a detector OR you are sampling a 5 MHz bandwidth of interest and taking a FFT (which is consistent with the rest of your description). Either approach can be used and you see both in the implementation of Spectrum Analyzer instruments. I assume the use of the word "scan" is figurative and you are sampling an analog BW of 5 MHz and then "scanning" by taking a FFT of that bandwidth. (Which is a very reasonable approach to take). However if you were actually scanning, the rate of scan would be important to limit. I don't think you are doing that, so I won't go into the further considerations of scan rate.



Consistent with Stanley's first point, you really need to understand the average occupied bandwidth of these "unknown tones" when specifying their expected power level. Just to clarify first any "matched filtering" techniques: If we knew anything further about the time varying characteristics of the "tones", we could use matched filtering techniques to optimize detection, consistent with what Marcus was pointing out with the FFT as just one example of doing that; which is a good choice for the detection of pure tones specifically up to the limits of our own oscillator phase noise and stability in our receiver--- Stanley is spot on in that pure tones don't exist, so reality sets a limit on how far we can take that, and further since you called these "unknown" and hinted this is EMI radiation noise I suspect that any other elaborate matched filtering techniques would not be easily done. (However! If you do know of particular patterns the electronics is doing, then that could indeed be exploited). Another example of using this technique to pull signals "out of the noise" is CDMA where for example Walsh codes could be used; here we know the signals are modulated by those specific codes, so we can "match" them in the receiver to provide the correlation gain described. It is interesting to compare the decoding matrix for the FFT (or OFDM specifically) to Walsh codes; in both cases we are correlating to code sequences; the Walsh codes are all two symbols (1, -1) while the FFT allows for doing the same thing with a full complex set on the unit circle.



However without knowing such detailed information about the transmitted signal, the first strategy would be simple bandpass filtering if the actual occupied power spectral density of the signal of interest is higher than our limit set by the thermal noise floor.



Let's go through a calculation to see what bandwidth you would need and what considerations you would make and how this "simple bandpass filtering" requirement translates to number of points needed in the FFT.



First we need to decide on a detection margin, typical numbers range from +6 dB to +12 dB, and are derived from probability of false alarm vs probability of detection which is the trade space. For simple computation I will use a reasonable number of +10 dB. This means if the noise in my detector is 10 dB below the signal of interest, I can make a reasonably confident detection on the presence of the signal.



Specifically for this case with AWGN noise the probability of false alarm would be $2 Q(3.16) = 0.16%$ from $10^{10 text{ dB}/20} = 3.16$ and the related area under the tails of the Gaussian distribution.



Given the signal level of -140 dBm, this implies a desired noise floor of -150 dBm.



To know what our noise floor is for a given filtering bandwidth, we need to know the receiver noise figure, which must account for all noise contributions up to the detector (including ADC quantization noise which can be included in a classical cascaded noise figure calculation). For purpose of proceeding with this example, I will assume a receiver noise figure of 3 dB. (You can change this to whatever your noise figure is, but given your objective, you would want to be sure you know what this is and that it is well designed).



Therefore the noise floor density is $-174 text{ dBm/Hz} + 3 text{ dB} = -171 text{ dBm/Hz}$, where $-174 text{ dBm/Hz}$ is the thermal noise floor at room temperature as computed from Boltzmann's constant and the temperature ($kT$).



For a total noise power of -150 dBm, which is 21 dB above the noise density, this is an implied bandwidth of $10^{21/10}= 126 text{ Hz} $



If you know that the signal of interest occupies a bandwidth of 126 Hz or less, or more specifically in that bandwidth maintains a power level of -140 dBm or more, then you have every opportunity to detect that signal with simple digital filtering techniques (just filter the occupied bandwidth). You can change the numbers above based on your actual system, but this would be the first thing I would look at in terms of getting there simply.



If you want more information such as what specific frequency that signal may be in, or if you know the signal meets that constraint but from measurement to measurement the signal location may change, or it occupies several of these bandwidth "bins", then the FFT is an excellent choice for that since it is essentially a bank of such filters.



This drives the minimum number of points required in the FFT which sets the resolution bandwidth (RBW) given that $RBW = f_s/N$ where N is the number of non-padded FFT samples. You didn't mention the sampling rate of your ADC or more specifically the sampling rate at the FFT computation, but for practical reasons I will assume a minimum sampling rate of 7.5 MHz at the FFT computation (allowing for simple anti-alias filtering ahead of your ADC, and ADC 5 MHz bandpass sampling of a real signal. Therefore to achieve the desired resolution bandwidth of 126 Hz, the number of points required in the FFT must be:



$$7.5 text{ MHz}/ 126 text{ Hz} = 59,500$$



Taking advantage of radix-2 implementations, I would use the next higher power of 2 to get $2^{16} = 65,536$ points



At this point there are several strategies to achieve this if not directly (such as sub-banding if you have post-processing time but limited resources), so the main point is to know what is the spectral density of your signal, and what is the actual noise floor (noise figure) of your receiver. In terms of spectral density, not total power but power / Hz, as long as the signal is indeed NOT below your noise, then detecting the signal will be no issue.






share|improve this answer























  • I can see how an FFT can pull out the signal based on spectral density of the signal and not the total power where it was my oversight. By scanning, it has 2 meanings in this project, first, scanning for a signal in the occupied bandwidth and second, scanning throughout some well known frequencies like 2.4GHz, 5.8GHz, etc using the same 5Mhz BW.
    – luffyKun
    yesterday










  • Yes so as long as you have sufficient margin against the theoretical thermal noise floor limits (and design your receiver properly)- doing that should not be overly challenging — it is straight forward to capture a 5 MHz band with an ADC and to do the FFT on the data and further post process. The key is if the spectral density of the signal is above the spectral density of the noise. To check your receiver noise floor, you can terminate your antenna port and do a capture, and then repeat with a calibrated input signal through the antenna connector port — a tone should suffice unless ...
    – Dan Boschen
    yesterday










  • you have excessive passband ripple (which is why true noise figure measurements measure receiver gain using elevated /calibrated noise sources that have a flat response across the passband of interest... if you have +/-1 dB of passband ripple then your noise figure measurement could be off by up to +/- 1 dB. I hope that makes sense. Bottom line in this comment is to validate where your noise floor sensitivity is and how far off you are from the theoretical limit established by $kTB$. By doing this test through your whole system including the FFT computation you will account for all factors.
    – Dan Boschen
    yesterday















up vote
4
down vote



accepted










65,536 point FFT, assuming a 3 dB overall receiver noise figure and a 7.5 MHz FFT sampling rate of a digitally down-coverted 5 MHz bandpass signal.



Sub-band the 5 MHz bandwidth if you have the time margin for post processing, and the number of points needed goes down accordingly.



To meet your objective we basically need a receiver with a resolution bandwidth of 126 Hz or less (assuming the 3 dB noise figure stated), as long as the -140 dBm power level stated for the signal of interest is in an occupied bandwidth of less than this. Notice the point of interest to determine our ability to detect is not what the total power is, but what is the power per unit Hz; the power spectral density!



Let me explain...



Both what Marcus and Stanley said are quite good and this will add some practicality to what you are doing specific to your "below the noise assumptions". It is a bit of a misnomer to say that the signal is below the noise when we only consider total power in a given bandwidth. What we really want to look at is power spectral density (power per unit Hz) of the signal as compared to the noise and then decide if it is truly below the noise floor or not.(the power spectral density of the demodulated signal at the decision detector specifically when we "match filter", which from your description does not sound like doing any demodulation is feasible in your case). If it is truly below the noise floor, then we are challenged. So as long as the power spectral density of the signal is well above that of the noise, we can proceed with simple techniques of detection.



You mention a "scan BW" which can imply you are actually "scanning" by translating an input frequency from an observation of a 5 MHz bandwidth of interest through a narrow observation filter and then to a detector OR you are sampling a 5 MHz bandwidth of interest and taking a FFT (which is consistent with the rest of your description). Either approach can be used and you see both in the implementation of Spectrum Analyzer instruments. I assume the use of the word "scan" is figurative and you are sampling an analog BW of 5 MHz and then "scanning" by taking a FFT of that bandwidth. (Which is a very reasonable approach to take). However if you were actually scanning, the rate of scan would be important to limit. I don't think you are doing that, so I won't go into the further considerations of scan rate.



Consistent with Stanley's first point, you really need to understand the average occupied bandwidth of these "unknown tones" when specifying their expected power level. Just to clarify first any "matched filtering" techniques: If we knew anything further about the time varying characteristics of the "tones", we could use matched filtering techniques to optimize detection, consistent with what Marcus was pointing out with the FFT as just one example of doing that; which is a good choice for the detection of pure tones specifically up to the limits of our own oscillator phase noise and stability in our receiver--- Stanley is spot on in that pure tones don't exist, so reality sets a limit on how far we can take that, and further since you called these "unknown" and hinted this is EMI radiation noise I suspect that any other elaborate matched filtering techniques would not be easily done. (However! If you do know of particular patterns the electronics is doing, then that could indeed be exploited). Another example of using this technique to pull signals "out of the noise" is CDMA where for example Walsh codes could be used; here we know the signals are modulated by those specific codes, so we can "match" them in the receiver to provide the correlation gain described. It is interesting to compare the decoding matrix for the FFT (or OFDM specifically) to Walsh codes; in both cases we are correlating to code sequences; the Walsh codes are all two symbols (1, -1) while the FFT allows for doing the same thing with a full complex set on the unit circle.



However without knowing such detailed information about the transmitted signal, the first strategy would be simple bandpass filtering if the actual occupied power spectral density of the signal of interest is higher than our limit set by the thermal noise floor.



Let's go through a calculation to see what bandwidth you would need and what considerations you would make and how this "simple bandpass filtering" requirement translates to number of points needed in the FFT.



First we need to decide on a detection margin, typical numbers range from +6 dB to +12 dB, and are derived from probability of false alarm vs probability of detection which is the trade space. For simple computation I will use a reasonable number of +10 dB. This means if the noise in my detector is 10 dB below the signal of interest, I can make a reasonably confident detection on the presence of the signal.



Specifically for this case with AWGN noise the probability of false alarm would be $2 Q(3.16) = 0.16%$ from $10^{10 text{ dB}/20} = 3.16$ and the related area under the tails of the Gaussian distribution.



Given the signal level of -140 dBm, this implies a desired noise floor of -150 dBm.



To know what our noise floor is for a given filtering bandwidth, we need to know the receiver noise figure, which must account for all noise contributions up to the detector (including ADC quantization noise which can be included in a classical cascaded noise figure calculation). For purpose of proceeding with this example, I will assume a receiver noise figure of 3 dB. (You can change this to whatever your noise figure is, but given your objective, you would want to be sure you know what this is and that it is well designed).



Therefore the noise floor density is $-174 text{ dBm/Hz} + 3 text{ dB} = -171 text{ dBm/Hz}$, where $-174 text{ dBm/Hz}$ is the thermal noise floor at room temperature as computed from Boltzmann's constant and the temperature ($kT$).



For a total noise power of -150 dBm, which is 21 dB above the noise density, this is an implied bandwidth of $10^{21/10}= 126 text{ Hz} $



If you know that the signal of interest occupies a bandwidth of 126 Hz or less, or more specifically in that bandwidth maintains a power level of -140 dBm or more, then you have every opportunity to detect that signal with simple digital filtering techniques (just filter the occupied bandwidth). You can change the numbers above based on your actual system, but this would be the first thing I would look at in terms of getting there simply.



If you want more information such as what specific frequency that signal may be in, or if you know the signal meets that constraint but from measurement to measurement the signal location may change, or it occupies several of these bandwidth "bins", then the FFT is an excellent choice for that since it is essentially a bank of such filters.



This drives the minimum number of points required in the FFT which sets the resolution bandwidth (RBW) given that $RBW = f_s/N$ where N is the number of non-padded FFT samples. You didn't mention the sampling rate of your ADC or more specifically the sampling rate at the FFT computation, but for practical reasons I will assume a minimum sampling rate of 7.5 MHz at the FFT computation (allowing for simple anti-alias filtering ahead of your ADC, and ADC 5 MHz bandpass sampling of a real signal. Therefore to achieve the desired resolution bandwidth of 126 Hz, the number of points required in the FFT must be:



$$7.5 text{ MHz}/ 126 text{ Hz} = 59,500$$



Taking advantage of radix-2 implementations, I would use the next higher power of 2 to get $2^{16} = 65,536$ points



At this point there are several strategies to achieve this if not directly (such as sub-banding if you have post-processing time but limited resources), so the main point is to know what is the spectral density of your signal, and what is the actual noise floor (noise figure) of your receiver. In terms of spectral density, not total power but power / Hz, as long as the signal is indeed NOT below your noise, then detecting the signal will be no issue.






share|improve this answer























  • I can see how an FFT can pull out the signal based on spectral density of the signal and not the total power where it was my oversight. By scanning, it has 2 meanings in this project, first, scanning for a signal in the occupied bandwidth and second, scanning throughout some well known frequencies like 2.4GHz, 5.8GHz, etc using the same 5Mhz BW.
    – luffyKun
    yesterday










  • Yes so as long as you have sufficient margin against the theoretical thermal noise floor limits (and design your receiver properly)- doing that should not be overly challenging — it is straight forward to capture a 5 MHz band with an ADC and to do the FFT on the data and further post process. The key is if the spectral density of the signal is above the spectral density of the noise. To check your receiver noise floor, you can terminate your antenna port and do a capture, and then repeat with a calibrated input signal through the antenna connector port — a tone should suffice unless ...
    – Dan Boschen
    yesterday










  • you have excessive passband ripple (which is why true noise figure measurements measure receiver gain using elevated /calibrated noise sources that have a flat response across the passband of interest... if you have +/-1 dB of passband ripple then your noise figure measurement could be off by up to +/- 1 dB. I hope that makes sense. Bottom line in this comment is to validate where your noise floor sensitivity is and how far off you are from the theoretical limit established by $kTB$. By doing this test through your whole system including the FFT computation you will account for all factors.
    – Dan Boschen
    yesterday













up vote
4
down vote



accepted







up vote
4
down vote



accepted






65,536 point FFT, assuming a 3 dB overall receiver noise figure and a 7.5 MHz FFT sampling rate of a digitally down-coverted 5 MHz bandpass signal.



Sub-band the 5 MHz bandwidth if you have the time margin for post processing, and the number of points needed goes down accordingly.



To meet your objective we basically need a receiver with a resolution bandwidth of 126 Hz or less (assuming the 3 dB noise figure stated), as long as the -140 dBm power level stated for the signal of interest is in an occupied bandwidth of less than this. Notice the point of interest to determine our ability to detect is not what the total power is, but what is the power per unit Hz; the power spectral density!



Let me explain...



Both what Marcus and Stanley said are quite good and this will add some practicality to what you are doing specific to your "below the noise assumptions". It is a bit of a misnomer to say that the signal is below the noise when we only consider total power in a given bandwidth. What we really want to look at is power spectral density (power per unit Hz) of the signal as compared to the noise and then decide if it is truly below the noise floor or not.(the power spectral density of the demodulated signal at the decision detector specifically when we "match filter", which from your description does not sound like doing any demodulation is feasible in your case). If it is truly below the noise floor, then we are challenged. So as long as the power spectral density of the signal is well above that of the noise, we can proceed with simple techniques of detection.



You mention a "scan BW" which can imply you are actually "scanning" by translating an input frequency from an observation of a 5 MHz bandwidth of interest through a narrow observation filter and then to a detector OR you are sampling a 5 MHz bandwidth of interest and taking a FFT (which is consistent with the rest of your description). Either approach can be used and you see both in the implementation of Spectrum Analyzer instruments. I assume the use of the word "scan" is figurative and you are sampling an analog BW of 5 MHz and then "scanning" by taking a FFT of that bandwidth. (Which is a very reasonable approach to take). However if you were actually scanning, the rate of scan would be important to limit. I don't think you are doing that, so I won't go into the further considerations of scan rate.



Consistent with Stanley's first point, you really need to understand the average occupied bandwidth of these "unknown tones" when specifying their expected power level. Just to clarify first any "matched filtering" techniques: If we knew anything further about the time varying characteristics of the "tones", we could use matched filtering techniques to optimize detection, consistent with what Marcus was pointing out with the FFT as just one example of doing that; which is a good choice for the detection of pure tones specifically up to the limits of our own oscillator phase noise and stability in our receiver--- Stanley is spot on in that pure tones don't exist, so reality sets a limit on how far we can take that, and further since you called these "unknown" and hinted this is EMI radiation noise I suspect that any other elaborate matched filtering techniques would not be easily done. (However! If you do know of particular patterns the electronics is doing, then that could indeed be exploited). Another example of using this technique to pull signals "out of the noise" is CDMA where for example Walsh codes could be used; here we know the signals are modulated by those specific codes, so we can "match" them in the receiver to provide the correlation gain described. It is interesting to compare the decoding matrix for the FFT (or OFDM specifically) to Walsh codes; in both cases we are correlating to code sequences; the Walsh codes are all two symbols (1, -1) while the FFT allows for doing the same thing with a full complex set on the unit circle.



However without knowing such detailed information about the transmitted signal, the first strategy would be simple bandpass filtering if the actual occupied power spectral density of the signal of interest is higher than our limit set by the thermal noise floor.



Let's go through a calculation to see what bandwidth you would need and what considerations you would make and how this "simple bandpass filtering" requirement translates to number of points needed in the FFT.



First we need to decide on a detection margin, typical numbers range from +6 dB to +12 dB, and are derived from probability of false alarm vs probability of detection which is the trade space. For simple computation I will use a reasonable number of +10 dB. This means if the noise in my detector is 10 dB below the signal of interest, I can make a reasonably confident detection on the presence of the signal.



Specifically for this case with AWGN noise the probability of false alarm would be $2 Q(3.16) = 0.16%$ from $10^{10 text{ dB}/20} = 3.16$ and the related area under the tails of the Gaussian distribution.



Given the signal level of -140 dBm, this implies a desired noise floor of -150 dBm.



To know what our noise floor is for a given filtering bandwidth, we need to know the receiver noise figure, which must account for all noise contributions up to the detector (including ADC quantization noise which can be included in a classical cascaded noise figure calculation). For purpose of proceeding with this example, I will assume a receiver noise figure of 3 dB. (You can change this to whatever your noise figure is, but given your objective, you would want to be sure you know what this is and that it is well designed).



Therefore the noise floor density is $-174 text{ dBm/Hz} + 3 text{ dB} = -171 text{ dBm/Hz}$, where $-174 text{ dBm/Hz}$ is the thermal noise floor at room temperature as computed from Boltzmann's constant and the temperature ($kT$).



For a total noise power of -150 dBm, which is 21 dB above the noise density, this is an implied bandwidth of $10^{21/10}= 126 text{ Hz} $



If you know that the signal of interest occupies a bandwidth of 126 Hz or less, or more specifically in that bandwidth maintains a power level of -140 dBm or more, then you have every opportunity to detect that signal with simple digital filtering techniques (just filter the occupied bandwidth). You can change the numbers above based on your actual system, but this would be the first thing I would look at in terms of getting there simply.



If you want more information such as what specific frequency that signal may be in, or if you know the signal meets that constraint but from measurement to measurement the signal location may change, or it occupies several of these bandwidth "bins", then the FFT is an excellent choice for that since it is essentially a bank of such filters.



This drives the minimum number of points required in the FFT which sets the resolution bandwidth (RBW) given that $RBW = f_s/N$ where N is the number of non-padded FFT samples. You didn't mention the sampling rate of your ADC or more specifically the sampling rate at the FFT computation, but for practical reasons I will assume a minimum sampling rate of 7.5 MHz at the FFT computation (allowing for simple anti-alias filtering ahead of your ADC, and ADC 5 MHz bandpass sampling of a real signal. Therefore to achieve the desired resolution bandwidth of 126 Hz, the number of points required in the FFT must be:



$$7.5 text{ MHz}/ 126 text{ Hz} = 59,500$$



Taking advantage of radix-2 implementations, I would use the next higher power of 2 to get $2^{16} = 65,536$ points



At this point there are several strategies to achieve this if not directly (such as sub-banding if you have post-processing time but limited resources), so the main point is to know what is the spectral density of your signal, and what is the actual noise floor (noise figure) of your receiver. In terms of spectral density, not total power but power / Hz, as long as the signal is indeed NOT below your noise, then detecting the signal will be no issue.






share|improve this answer














65,536 point FFT, assuming a 3 dB overall receiver noise figure and a 7.5 MHz FFT sampling rate of a digitally down-coverted 5 MHz bandpass signal.



Sub-band the 5 MHz bandwidth if you have the time margin for post processing, and the number of points needed goes down accordingly.



To meet your objective we basically need a receiver with a resolution bandwidth of 126 Hz or less (assuming the 3 dB noise figure stated), as long as the -140 dBm power level stated for the signal of interest is in an occupied bandwidth of less than this. Notice the point of interest to determine our ability to detect is not what the total power is, but what is the power per unit Hz; the power spectral density!



Let me explain...



Both what Marcus and Stanley said are quite good and this will add some practicality to what you are doing specific to your "below the noise assumptions". It is a bit of a misnomer to say that the signal is below the noise when we only consider total power in a given bandwidth. What we really want to look at is power spectral density (power per unit Hz) of the signal as compared to the noise and then decide if it is truly below the noise floor or not.(the power spectral density of the demodulated signal at the decision detector specifically when we "match filter", which from your description does not sound like doing any demodulation is feasible in your case). If it is truly below the noise floor, then we are challenged. So as long as the power spectral density of the signal is well above that of the noise, we can proceed with simple techniques of detection.



You mention a "scan BW" which can imply you are actually "scanning" by translating an input frequency from an observation of a 5 MHz bandwidth of interest through a narrow observation filter and then to a detector OR you are sampling a 5 MHz bandwidth of interest and taking a FFT (which is consistent with the rest of your description). Either approach can be used and you see both in the implementation of Spectrum Analyzer instruments. I assume the use of the word "scan" is figurative and you are sampling an analog BW of 5 MHz and then "scanning" by taking a FFT of that bandwidth. (Which is a very reasonable approach to take). However if you were actually scanning, the rate of scan would be important to limit. I don't think you are doing that, so I won't go into the further considerations of scan rate.



Consistent with Stanley's first point, you really need to understand the average occupied bandwidth of these "unknown tones" when specifying their expected power level. Just to clarify first any "matched filtering" techniques: If we knew anything further about the time varying characteristics of the "tones", we could use matched filtering techniques to optimize detection, consistent with what Marcus was pointing out with the FFT as just one example of doing that; which is a good choice for the detection of pure tones specifically up to the limits of our own oscillator phase noise and stability in our receiver--- Stanley is spot on in that pure tones don't exist, so reality sets a limit on how far we can take that, and further since you called these "unknown" and hinted this is EMI radiation noise I suspect that any other elaborate matched filtering techniques would not be easily done. (However! If you do know of particular patterns the electronics is doing, then that could indeed be exploited). Another example of using this technique to pull signals "out of the noise" is CDMA where for example Walsh codes could be used; here we know the signals are modulated by those specific codes, so we can "match" them in the receiver to provide the correlation gain described. It is interesting to compare the decoding matrix for the FFT (or OFDM specifically) to Walsh codes; in both cases we are correlating to code sequences; the Walsh codes are all two symbols (1, -1) while the FFT allows for doing the same thing with a full complex set on the unit circle.



However without knowing such detailed information about the transmitted signal, the first strategy would be simple bandpass filtering if the actual occupied power spectral density of the signal of interest is higher than our limit set by the thermal noise floor.



Let's go through a calculation to see what bandwidth you would need and what considerations you would make and how this "simple bandpass filtering" requirement translates to number of points needed in the FFT.



First we need to decide on a detection margin, typical numbers range from +6 dB to +12 dB, and are derived from probability of false alarm vs probability of detection which is the trade space. For simple computation I will use a reasonable number of +10 dB. This means if the noise in my detector is 10 dB below the signal of interest, I can make a reasonably confident detection on the presence of the signal.



Specifically for this case with AWGN noise the probability of false alarm would be $2 Q(3.16) = 0.16%$ from $10^{10 text{ dB}/20} = 3.16$ and the related area under the tails of the Gaussian distribution.



Given the signal level of -140 dBm, this implies a desired noise floor of -150 dBm.



To know what our noise floor is for a given filtering bandwidth, we need to know the receiver noise figure, which must account for all noise contributions up to the detector (including ADC quantization noise which can be included in a classical cascaded noise figure calculation). For purpose of proceeding with this example, I will assume a receiver noise figure of 3 dB. (You can change this to whatever your noise figure is, but given your objective, you would want to be sure you know what this is and that it is well designed).



Therefore the noise floor density is $-174 text{ dBm/Hz} + 3 text{ dB} = -171 text{ dBm/Hz}$, where $-174 text{ dBm/Hz}$ is the thermal noise floor at room temperature as computed from Boltzmann's constant and the temperature ($kT$).



For a total noise power of -150 dBm, which is 21 dB above the noise density, this is an implied bandwidth of $10^{21/10}= 126 text{ Hz} $



If you know that the signal of interest occupies a bandwidth of 126 Hz or less, or more specifically in that bandwidth maintains a power level of -140 dBm or more, then you have every opportunity to detect that signal with simple digital filtering techniques (just filter the occupied bandwidth). You can change the numbers above based on your actual system, but this would be the first thing I would look at in terms of getting there simply.



If you want more information such as what specific frequency that signal may be in, or if you know the signal meets that constraint but from measurement to measurement the signal location may change, or it occupies several of these bandwidth "bins", then the FFT is an excellent choice for that since it is essentially a bank of such filters.



This drives the minimum number of points required in the FFT which sets the resolution bandwidth (RBW) given that $RBW = f_s/N$ where N is the number of non-padded FFT samples. You didn't mention the sampling rate of your ADC or more specifically the sampling rate at the FFT computation, but for practical reasons I will assume a minimum sampling rate of 7.5 MHz at the FFT computation (allowing for simple anti-alias filtering ahead of your ADC, and ADC 5 MHz bandpass sampling of a real signal. Therefore to achieve the desired resolution bandwidth of 126 Hz, the number of points required in the FFT must be:



$$7.5 text{ MHz}/ 126 text{ Hz} = 59,500$$



Taking advantage of radix-2 implementations, I would use the next higher power of 2 to get $2^{16} = 65,536$ points



At this point there are several strategies to achieve this if not directly (such as sub-banding if you have post-processing time but limited resources), so the main point is to know what is the spectral density of your signal, and what is the actual noise floor (noise figure) of your receiver. In terms of spectral density, not total power but power / Hz, as long as the signal is indeed NOT below your noise, then detecting the signal will be no issue.







share|improve this answer














share|improve this answer



share|improve this answer








edited 2 days ago

























answered 2 days ago









Dan Boschen

9,75621037




9,75621037












  • I can see how an FFT can pull out the signal based on spectral density of the signal and not the total power where it was my oversight. By scanning, it has 2 meanings in this project, first, scanning for a signal in the occupied bandwidth and second, scanning throughout some well known frequencies like 2.4GHz, 5.8GHz, etc using the same 5Mhz BW.
    – luffyKun
    yesterday










  • Yes so as long as you have sufficient margin against the theoretical thermal noise floor limits (and design your receiver properly)- doing that should not be overly challenging — it is straight forward to capture a 5 MHz band with an ADC and to do the FFT on the data and further post process. The key is if the spectral density of the signal is above the spectral density of the noise. To check your receiver noise floor, you can terminate your antenna port and do a capture, and then repeat with a calibrated input signal through the antenna connector port — a tone should suffice unless ...
    – Dan Boschen
    yesterday










  • you have excessive passband ripple (which is why true noise figure measurements measure receiver gain using elevated /calibrated noise sources that have a flat response across the passband of interest... if you have +/-1 dB of passband ripple then your noise figure measurement could be off by up to +/- 1 dB. I hope that makes sense. Bottom line in this comment is to validate where your noise floor sensitivity is and how far off you are from the theoretical limit established by $kTB$. By doing this test through your whole system including the FFT computation you will account for all factors.
    – Dan Boschen
    yesterday


















  • I can see how an FFT can pull out the signal based on spectral density of the signal and not the total power where it was my oversight. By scanning, it has 2 meanings in this project, first, scanning for a signal in the occupied bandwidth and second, scanning throughout some well known frequencies like 2.4GHz, 5.8GHz, etc using the same 5Mhz BW.
    – luffyKun
    yesterday










  • Yes so as long as you have sufficient margin against the theoretical thermal noise floor limits (and design your receiver properly)- doing that should not be overly challenging — it is straight forward to capture a 5 MHz band with an ADC and to do the FFT on the data and further post process. The key is if the spectral density of the signal is above the spectral density of the noise. To check your receiver noise floor, you can terminate your antenna port and do a capture, and then repeat with a calibrated input signal through the antenna connector port — a tone should suffice unless ...
    – Dan Boschen
    yesterday










  • you have excessive passband ripple (which is why true noise figure measurements measure receiver gain using elevated /calibrated noise sources that have a flat response across the passband of interest... if you have +/-1 dB of passband ripple then your noise figure measurement could be off by up to +/- 1 dB. I hope that makes sense. Bottom line in this comment is to validate where your noise floor sensitivity is and how far off you are from the theoretical limit established by $kTB$. By doing this test through your whole system including the FFT computation you will account for all factors.
    – Dan Boschen
    yesterday
















I can see how an FFT can pull out the signal based on spectral density of the signal and not the total power where it was my oversight. By scanning, it has 2 meanings in this project, first, scanning for a signal in the occupied bandwidth and second, scanning throughout some well known frequencies like 2.4GHz, 5.8GHz, etc using the same 5Mhz BW.
– luffyKun
yesterday




I can see how an FFT can pull out the signal based on spectral density of the signal and not the total power where it was my oversight. By scanning, it has 2 meanings in this project, first, scanning for a signal in the occupied bandwidth and second, scanning throughout some well known frequencies like 2.4GHz, 5.8GHz, etc using the same 5Mhz BW.
– luffyKun
yesterday












Yes so as long as you have sufficient margin against the theoretical thermal noise floor limits (and design your receiver properly)- doing that should not be overly challenging — it is straight forward to capture a 5 MHz band with an ADC and to do the FFT on the data and further post process. The key is if the spectral density of the signal is above the spectral density of the noise. To check your receiver noise floor, you can terminate your antenna port and do a capture, and then repeat with a calibrated input signal through the antenna connector port — a tone should suffice unless ...
– Dan Boschen
yesterday




Yes so as long as you have sufficient margin against the theoretical thermal noise floor limits (and design your receiver properly)- doing that should not be overly challenging — it is straight forward to capture a 5 MHz band with an ADC and to do the FFT on the data and further post process. The key is if the spectral density of the signal is above the spectral density of the noise. To check your receiver noise floor, you can terminate your antenna port and do a capture, and then repeat with a calibrated input signal through the antenna connector port — a tone should suffice unless ...
– Dan Boschen
yesterday












you have excessive passband ripple (which is why true noise figure measurements measure receiver gain using elevated /calibrated noise sources that have a flat response across the passband of interest... if you have +/-1 dB of passband ripple then your noise figure measurement could be off by up to +/- 1 dB. I hope that makes sense. Bottom line in this comment is to validate where your noise floor sensitivity is and how far off you are from the theoretical limit established by $kTB$. By doing this test through your whole system including the FFT computation you will account for all factors.
– Dan Boschen
yesterday




you have excessive passband ripple (which is why true noise figure measurements measure receiver gain using elevated /calibrated noise sources that have a flat response across the passband of interest... if you have +/-1 dB of passband ripple then your noise figure measurement could be off by up to +/- 1 dB. I hope that makes sense. Bottom line in this comment is to validate where your noise floor sensitivity is and how far off you are from the theoretical limit established by $kTB$. By doing this test through your whole system including the FFT computation you will account for all factors.
– Dan Boschen
yesterday










up vote
7
down vote













If you look at the formula of a single DFT bin



$$X[k] = sum_{n=0}^{N-1}x[n]e^{-j2pi kfrac nN}text,$$



you'll notice that his is essentially a correlation of $x$ with the complex sinusoid $e^{-j2pi kfrac nN}$.



That means the DFT can just be understood as a filter bank of matched filters for single tones that fall in the DFT "raster".



Hence, you simply get FFT length-based processing gain: The length of the sum.



But: you probably don't have perfect knowledge of the exact frequency of the signal you're trying to detect¹! So, you can't put things into that perfect DFT raster.



Now, the larger you choose the FFT length $N$, the finer that raster will get, but also, the longer your observation has to be, and the more compute power you'll need.



At some point, the DFT stops being the best possible tone detector, and superresolution techniques become relevant. In this case (weak tone, you're sure that you've only got exactly one tone in your signal), the ESPRIT algorithm with a long observation period leading to the autocovariance matrix estimate that it takes as input, would probably work very nicely.




¹ There's inevitably frequency error in your receiver, and in your transmitter. Papers that start with We assume perfect synchronization typically skip the hard part of making a system work...




share|improve this answer























  • the matched filter is out performed by ESPRIT? I don’t think so
    – Stanley Pawlukiewicz
    Nov 28 at 5:48










  • no, but the filter is only matched if you "hit" the frequency of that bin perfectly – which you, in an estimation problem, don't. (Otherwise: Welch's method, don't do the full FFT).
    – Marcus Müller
    Nov 28 at 11:41












  • the loss of a small mismatch that gets smaller as you lengthen will outperform a nonlinear estimators threshold behavior. no matched filter is perfect. ESPIRIT assumes white noise as well. No sample autocorrelation matrix is perfectly rotational either. A DFT bank is mote robust
    – Stanley Pawlukiewicz
    Nov 28 at 12:34










  • Well, don't forget that you redistribute your tone's energy over multiple bin according to a sinc shape in a DFT. The point is that we need to compare the variance in AWGN of the energy estimate of an "falls in the middle between two bins" tone of an $N$-point DFT's $max |cdot|$ with the variance of an ESPRIT estimate that incorporated the same $N$ samples into its autocorrelation matrix estimate.
    – Marcus Müller
    Nov 28 at 13:13






  • 1




    @Marcus, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:29















up vote
7
down vote













If you look at the formula of a single DFT bin



$$X[k] = sum_{n=0}^{N-1}x[n]e^{-j2pi kfrac nN}text,$$



you'll notice that his is essentially a correlation of $x$ with the complex sinusoid $e^{-j2pi kfrac nN}$.



That means the DFT can just be understood as a filter bank of matched filters for single tones that fall in the DFT "raster".



Hence, you simply get FFT length-based processing gain: The length of the sum.



But: you probably don't have perfect knowledge of the exact frequency of the signal you're trying to detect¹! So, you can't put things into that perfect DFT raster.



Now, the larger you choose the FFT length $N$, the finer that raster will get, but also, the longer your observation has to be, and the more compute power you'll need.



At some point, the DFT stops being the best possible tone detector, and superresolution techniques become relevant. In this case (weak tone, you're sure that you've only got exactly one tone in your signal), the ESPRIT algorithm with a long observation period leading to the autocovariance matrix estimate that it takes as input, would probably work very nicely.




¹ There's inevitably frequency error in your receiver, and in your transmitter. Papers that start with We assume perfect synchronization typically skip the hard part of making a system work...




share|improve this answer























  • the matched filter is out performed by ESPRIT? I don’t think so
    – Stanley Pawlukiewicz
    Nov 28 at 5:48










  • no, but the filter is only matched if you "hit" the frequency of that bin perfectly – which you, in an estimation problem, don't. (Otherwise: Welch's method, don't do the full FFT).
    – Marcus Müller
    Nov 28 at 11:41












  • the loss of a small mismatch that gets smaller as you lengthen will outperform a nonlinear estimators threshold behavior. no matched filter is perfect. ESPIRIT assumes white noise as well. No sample autocorrelation matrix is perfectly rotational either. A DFT bank is mote robust
    – Stanley Pawlukiewicz
    Nov 28 at 12:34










  • Well, don't forget that you redistribute your tone's energy over multiple bin according to a sinc shape in a DFT. The point is that we need to compare the variance in AWGN of the energy estimate of an "falls in the middle between two bins" tone of an $N$-point DFT's $max |cdot|$ with the variance of an ESPRIT estimate that incorporated the same $N$ samples into its autocorrelation matrix estimate.
    – Marcus Müller
    Nov 28 at 13:13






  • 1




    @Marcus, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:29













up vote
7
down vote










up vote
7
down vote









If you look at the formula of a single DFT bin



$$X[k] = sum_{n=0}^{N-1}x[n]e^{-j2pi kfrac nN}text,$$



you'll notice that his is essentially a correlation of $x$ with the complex sinusoid $e^{-j2pi kfrac nN}$.



That means the DFT can just be understood as a filter bank of matched filters for single tones that fall in the DFT "raster".



Hence, you simply get FFT length-based processing gain: The length of the sum.



But: you probably don't have perfect knowledge of the exact frequency of the signal you're trying to detect¹! So, you can't put things into that perfect DFT raster.



Now, the larger you choose the FFT length $N$, the finer that raster will get, but also, the longer your observation has to be, and the more compute power you'll need.



At some point, the DFT stops being the best possible tone detector, and superresolution techniques become relevant. In this case (weak tone, you're sure that you've only got exactly one tone in your signal), the ESPRIT algorithm with a long observation period leading to the autocovariance matrix estimate that it takes as input, would probably work very nicely.




¹ There's inevitably frequency error in your receiver, and in your transmitter. Papers that start with We assume perfect synchronization typically skip the hard part of making a system work...




share|improve this answer














If you look at the formula of a single DFT bin



$$X[k] = sum_{n=0}^{N-1}x[n]e^{-j2pi kfrac nN}text,$$



you'll notice that his is essentially a correlation of $x$ with the complex sinusoid $e^{-j2pi kfrac nN}$.



That means the DFT can just be understood as a filter bank of matched filters for single tones that fall in the DFT "raster".



Hence, you simply get FFT length-based processing gain: The length of the sum.



But: you probably don't have perfect knowledge of the exact frequency of the signal you're trying to detect¹! So, you can't put things into that perfect DFT raster.



Now, the larger you choose the FFT length $N$, the finer that raster will get, but also, the longer your observation has to be, and the more compute power you'll need.



At some point, the DFT stops being the best possible tone detector, and superresolution techniques become relevant. In this case (weak tone, you're sure that you've only got exactly one tone in your signal), the ESPRIT algorithm with a long observation period leading to the autocovariance matrix estimate that it takes as input, would probably work very nicely.




¹ There's inevitably frequency error in your receiver, and in your transmitter. Papers that start with We assume perfect synchronization typically skip the hard part of making a system work...





share|improve this answer














share|improve this answer



share|improve this answer








edited Nov 27 at 23:01

























answered Nov 27 at 22:53









Marcus Müller

11.3k41431




11.3k41431












  • the matched filter is out performed by ESPRIT? I don’t think so
    – Stanley Pawlukiewicz
    Nov 28 at 5:48










  • no, but the filter is only matched if you "hit" the frequency of that bin perfectly – which you, in an estimation problem, don't. (Otherwise: Welch's method, don't do the full FFT).
    – Marcus Müller
    Nov 28 at 11:41












  • the loss of a small mismatch that gets smaller as you lengthen will outperform a nonlinear estimators threshold behavior. no matched filter is perfect. ESPIRIT assumes white noise as well. No sample autocorrelation matrix is perfectly rotational either. A DFT bank is mote robust
    – Stanley Pawlukiewicz
    Nov 28 at 12:34










  • Well, don't forget that you redistribute your tone's energy over multiple bin according to a sinc shape in a DFT. The point is that we need to compare the variance in AWGN of the energy estimate of an "falls in the middle between two bins" tone of an $N$-point DFT's $max |cdot|$ with the variance of an ESPRIT estimate that incorporated the same $N$ samples into its autocorrelation matrix estimate.
    – Marcus Müller
    Nov 28 at 13:13






  • 1




    @Marcus, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:29


















  • the matched filter is out performed by ESPRIT? I don’t think so
    – Stanley Pawlukiewicz
    Nov 28 at 5:48










  • no, but the filter is only matched if you "hit" the frequency of that bin perfectly – which you, in an estimation problem, don't. (Otherwise: Welch's method, don't do the full FFT).
    – Marcus Müller
    Nov 28 at 11:41












  • the loss of a small mismatch that gets smaller as you lengthen will outperform a nonlinear estimators threshold behavior. no matched filter is perfect. ESPIRIT assumes white noise as well. No sample autocorrelation matrix is perfectly rotational either. A DFT bank is mote robust
    – Stanley Pawlukiewicz
    Nov 28 at 12:34










  • Well, don't forget that you redistribute your tone's energy over multiple bin according to a sinc shape in a DFT. The point is that we need to compare the variance in AWGN of the energy estimate of an "falls in the middle between two bins" tone of an $N$-point DFT's $max |cdot|$ with the variance of an ESPRIT estimate that incorporated the same $N$ samples into its autocorrelation matrix estimate.
    – Marcus Müller
    Nov 28 at 13:13






  • 1




    @Marcus, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:29
















the matched filter is out performed by ESPRIT? I don’t think so
– Stanley Pawlukiewicz
Nov 28 at 5:48




the matched filter is out performed by ESPRIT? I don’t think so
– Stanley Pawlukiewicz
Nov 28 at 5:48












no, but the filter is only matched if you "hit" the frequency of that bin perfectly – which you, in an estimation problem, don't. (Otherwise: Welch's method, don't do the full FFT).
– Marcus Müller
Nov 28 at 11:41






no, but the filter is only matched if you "hit" the frequency of that bin perfectly – which you, in an estimation problem, don't. (Otherwise: Welch's method, don't do the full FFT).
– Marcus Müller
Nov 28 at 11:41














the loss of a small mismatch that gets smaller as you lengthen will outperform a nonlinear estimators threshold behavior. no matched filter is perfect. ESPIRIT assumes white noise as well. No sample autocorrelation matrix is perfectly rotational either. A DFT bank is mote robust
– Stanley Pawlukiewicz
Nov 28 at 12:34




the loss of a small mismatch that gets smaller as you lengthen will outperform a nonlinear estimators threshold behavior. no matched filter is perfect. ESPIRIT assumes white noise as well. No sample autocorrelation matrix is perfectly rotational either. A DFT bank is mote robust
– Stanley Pawlukiewicz
Nov 28 at 12:34












Well, don't forget that you redistribute your tone's energy over multiple bin according to a sinc shape in a DFT. The point is that we need to compare the variance in AWGN of the energy estimate of an "falls in the middle between two bins" tone of an $N$-point DFT's $max |cdot|$ with the variance of an ESPRIT estimate that incorporated the same $N$ samples into its autocorrelation matrix estimate.
– Marcus Müller
Nov 28 at 13:13




Well, don't forget that you redistribute your tone's energy over multiple bin according to a sinc shape in a DFT. The point is that we need to compare the variance in AWGN of the energy estimate of an "falls in the middle between two bins" tone of an $N$-point DFT's $max |cdot|$ with the variance of an ESPRIT estimate that incorporated the same $N$ samples into its autocorrelation matrix estimate.
– Marcus Müller
Nov 28 at 13:13




1




1




@Marcus, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
– luffyKun
Nov 28 at 20:29




@Marcus, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
– luffyKun
Nov 28 at 20:29










up vote
5
down vote













To say there are only 2 problems with DFT based detection of weak tones would be wrong but I’m going to ignore myself and say there are two problems.



Problem 1:



A pure tone is a rare thing. It has to exist forever and never deviate from its tonal form. Real tones turn on and off, fade, and drift, and are often a component of a more complex waveforms. A real tone has bandwidth. One cannot arbitrarily increase the length of a DFT. One can run out of signal. One can over resolve a tone. One’s local time reference isn’t perfect.



Problem 2



Neglecting things like heavy tailed nonGaussian correlated noise and the tendency of real situations to have other tonal components in proximity, like looking for a weak tone in the presence of a unknown number of other tones.



An M point DFT produces M outputs. You need to pick the correct bin. This generally comes down to the “correct” bin being a reliable local maximum. The detection statistics of the maximum of a set of correlated bins is a hard problem. One usually relies on heuristics.



The finite observation and over resolution problem can be mitigated to some extent by combining coherent and incoherent gain. That is, averaging a bin amplitude over some number of coherent DFTs.



The DFT is not a consistent estimator. It doesn’t reduce the noise variance as the length of the DFT increases but it does provide SNR gain providing the tone is essentially tonal over its time window.



Averaging the bin power or bin magnitude does reduce variance. The combination of coherent and incoherent processing is a consistent estimate.



In a real application, one needs to find that sweet spot.



Im not telling you not to use a covariance based frequency estimator. ESPIRT was originally developed to solve a direction finding problem in array processing. It works well but there are a different set of tradeoffs in array processing even if the mathematics are nearly the same.






share|improve this answer





















  • Just now saw this answer! Awesome!
    – Marcus Müller
    Nov 28 at 17:54










  • @Stanley, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:38










  • I can’t say that Ive ever run a DFT that large. Expect to do some trial and error. I assume you are looking for a 20Hz BW
    – Stanley Pawlukiewicz
    Nov 28 at 21:50















up vote
5
down vote













To say there are only 2 problems with DFT based detection of weak tones would be wrong but I’m going to ignore myself and say there are two problems.



Problem 1:



A pure tone is a rare thing. It has to exist forever and never deviate from its tonal form. Real tones turn on and off, fade, and drift, and are often a component of a more complex waveforms. A real tone has bandwidth. One cannot arbitrarily increase the length of a DFT. One can run out of signal. One can over resolve a tone. One’s local time reference isn’t perfect.



Problem 2



Neglecting things like heavy tailed nonGaussian correlated noise and the tendency of real situations to have other tonal components in proximity, like looking for a weak tone in the presence of a unknown number of other tones.



An M point DFT produces M outputs. You need to pick the correct bin. This generally comes down to the “correct” bin being a reliable local maximum. The detection statistics of the maximum of a set of correlated bins is a hard problem. One usually relies on heuristics.



The finite observation and over resolution problem can be mitigated to some extent by combining coherent and incoherent gain. That is, averaging a bin amplitude over some number of coherent DFTs.



The DFT is not a consistent estimator. It doesn’t reduce the noise variance as the length of the DFT increases but it does provide SNR gain providing the tone is essentially tonal over its time window.



Averaging the bin power or bin magnitude does reduce variance. The combination of coherent and incoherent processing is a consistent estimate.



In a real application, one needs to find that sweet spot.



Im not telling you not to use a covariance based frequency estimator. ESPIRT was originally developed to solve a direction finding problem in array processing. It works well but there are a different set of tradeoffs in array processing even if the mathematics are nearly the same.






share|improve this answer





















  • Just now saw this answer! Awesome!
    – Marcus Müller
    Nov 28 at 17:54










  • @Stanley, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:38










  • I can’t say that Ive ever run a DFT that large. Expect to do some trial and error. I assume you are looking for a 20Hz BW
    – Stanley Pawlukiewicz
    Nov 28 at 21:50













up vote
5
down vote










up vote
5
down vote









To say there are only 2 problems with DFT based detection of weak tones would be wrong but I’m going to ignore myself and say there are two problems.



Problem 1:



A pure tone is a rare thing. It has to exist forever and never deviate from its tonal form. Real tones turn on and off, fade, and drift, and are often a component of a more complex waveforms. A real tone has bandwidth. One cannot arbitrarily increase the length of a DFT. One can run out of signal. One can over resolve a tone. One’s local time reference isn’t perfect.



Problem 2



Neglecting things like heavy tailed nonGaussian correlated noise and the tendency of real situations to have other tonal components in proximity, like looking for a weak tone in the presence of a unknown number of other tones.



An M point DFT produces M outputs. You need to pick the correct bin. This generally comes down to the “correct” bin being a reliable local maximum. The detection statistics of the maximum of a set of correlated bins is a hard problem. One usually relies on heuristics.



The finite observation and over resolution problem can be mitigated to some extent by combining coherent and incoherent gain. That is, averaging a bin amplitude over some number of coherent DFTs.



The DFT is not a consistent estimator. It doesn’t reduce the noise variance as the length of the DFT increases but it does provide SNR gain providing the tone is essentially tonal over its time window.



Averaging the bin power or bin magnitude does reduce variance. The combination of coherent and incoherent processing is a consistent estimate.



In a real application, one needs to find that sweet spot.



Im not telling you not to use a covariance based frequency estimator. ESPIRT was originally developed to solve a direction finding problem in array processing. It works well but there are a different set of tradeoffs in array processing even if the mathematics are nearly the same.






share|improve this answer












To say there are only 2 problems with DFT based detection of weak tones would be wrong but I’m going to ignore myself and say there are two problems.



Problem 1:



A pure tone is a rare thing. It has to exist forever and never deviate from its tonal form. Real tones turn on and off, fade, and drift, and are often a component of a more complex waveforms. A real tone has bandwidth. One cannot arbitrarily increase the length of a DFT. One can run out of signal. One can over resolve a tone. One’s local time reference isn’t perfect.



Problem 2



Neglecting things like heavy tailed nonGaussian correlated noise and the tendency of real situations to have other tonal components in proximity, like looking for a weak tone in the presence of a unknown number of other tones.



An M point DFT produces M outputs. You need to pick the correct bin. This generally comes down to the “correct” bin being a reliable local maximum. The detection statistics of the maximum of a set of correlated bins is a hard problem. One usually relies on heuristics.



The finite observation and over resolution problem can be mitigated to some extent by combining coherent and incoherent gain. That is, averaging a bin amplitude over some number of coherent DFTs.



The DFT is not a consistent estimator. It doesn’t reduce the noise variance as the length of the DFT increases but it does provide SNR gain providing the tone is essentially tonal over its time window.



Averaging the bin power or bin magnitude does reduce variance. The combination of coherent and incoherent processing is a consistent estimate.



In a real application, one needs to find that sweet spot.



Im not telling you not to use a covariance based frequency estimator. ESPIRT was originally developed to solve a direction finding problem in array processing. It works well but there are a different set of tradeoffs in array processing even if the mathematics are nearly the same.







share|improve this answer












share|improve this answer



share|improve this answer










answered Nov 28 at 15:34









Stanley Pawlukiewicz

5,8632421




5,8632421












  • Just now saw this answer! Awesome!
    – Marcus Müller
    Nov 28 at 17:54










  • @Stanley, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:38










  • I can’t say that Ive ever run a DFT that large. Expect to do some trial and error. I assume you are looking for a 20Hz BW
    – Stanley Pawlukiewicz
    Nov 28 at 21:50


















  • Just now saw this answer! Awesome!
    – Marcus Müller
    Nov 28 at 17:54










  • @Stanley, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
    – luffyKun
    Nov 28 at 20:38










  • I can’t say that Ive ever run a DFT that large. Expect to do some trial and error. I assume you are looking for a 20Hz BW
    – Stanley Pawlukiewicz
    Nov 28 at 21:50
















Just now saw this answer! Awesome!
– Marcus Müller
Nov 28 at 17:54




Just now saw this answer! Awesome!
– Marcus Müller
Nov 28 at 17:54












@Stanley, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
– luffyKun
Nov 28 at 20:38




@Stanley, It is not only one tone, it could be harmonics and some other unintended electromagnetic emissions. The receiver was already designed and implemented, it is an RFIC (LNA, Digital Filter and ADC), and I was thinking FFTs of 256k running on a hardware accelerator.
– luffyKun
Nov 28 at 20:38












I can’t say that Ive ever run a DFT that large. Expect to do some trial and error. I assume you are looking for a 20Hz BW
– Stanley Pawlukiewicz
Nov 28 at 21:50




I can’t say that Ive ever run a DFT that large. Expect to do some trial and error. I assume you are looking for a 20Hz BW
– Stanley Pawlukiewicz
Nov 28 at 21:50










luffyKun is a new contributor. Be nice, and check out our Code of Conduct.










draft saved

draft discarded


















luffyKun is a new contributor. Be nice, and check out our Code of Conduct.













luffyKun is a new contributor. Be nice, and check out our Code of Conduct.












luffyKun is a new contributor. Be nice, and check out our Code of Conduct.
















Thanks for contributing an answer to Signal Processing Stack Exchange!


  • Please be sure to answer the question. Provide details and share your research!

But avoid



  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.


Use MathJax to format equations. MathJax reference.


To learn more, see our tips on writing great answers.





Some of your past answers have not been well-received, and you're in danger of being blocked from answering.


Please pay close attention to the following guidance:


  • Please be sure to answer the question. Provide details and share your research!

But avoid



  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.


To learn more, see our tips on writing great answers.




draft saved


draft discarded














StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdsp.stackexchange.com%2fquestions%2f53709%2fhow-large-ffts-can-pull-signals-out-of-the-noise-floor%23new-answer', 'question_page');
}
);

Post as a guest















Required, but never shown





















































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown

































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown







Popular posts from this blog

AnyDesk - Fatal Program Failure

QoS: MAC-Priority for clients behind a repeater

Актюбинская область